3.12. Removal of an oil separator of system of ventilation of a case

 PERFORMANCE ORDER

We take out the index of level of oil (probe).

Having weakened collars, we disconnect big...

... and small hoses of ventilation of a case.

Key "on 13" we turn off a nut of fastening of a cover of a sapun.

We remove a sealing copper washer.

We uncover a sapuna...

... and laying of a cover.

We tighten two nuts of M8 on a hairpin and a key "on 13" we turn off it.

We take out a hairpin...

... and oil separator.

We wash out oil separator details gasoline then we establish them in the return sequence.